The Model 250 consists of a controller, dispense syringes and accessories. It is used to automatically or manually apply low to high viscosity materials. It incorporates automatic four range timing to control volume, adjustable pressure to control flow rate and an independently adjustable vacuum pullback system to prevent dripping. The unit is easily interfaced with jigs, fixtures, and automated equipment.
Operation: In the automatic mode, when the operator actuates the foot switch, regulated air is supplied to the syringe for a precise preset time. At the end of the timed pulse an independently regulated vacuum is automatically applied to stop the dispense and prevent dripping. When in the manual mode, operation is the same except that the duration of the air pulse is controlled by the length of time the operator actuates the foot switch. 5, 10, and 30 cc disposable syringes are standard, however, other capacities are available.
The 250A variation is operationally identical to the Model 250 except that the unit is fitted with a high capacity, ultra low drip pressure regulating system. Equipment package options and specifications are the same as the Model 250.
The 250VP unit is a vacuum pencil for the 250 or 250A model.
The system includes: One Tridak Model 250 controller One syringe stand One each 5, 10 and 30 cc aircaps Six each of 5, 10 and 30 cc syringes with pistons One external filter/regulator One package containing 15, 18, 20, 21, 22, 23 and 25 gauge needles One kwik chek valve Air hose and fittings C/P tips and adapter
Specifications: Power Required • 110 VAC, 50/60 Hz, 1/10 amp (220 VAC available) Air Required • 60 psi Controller Dimensions • 9 3/4 " W x 3 3/4 " H x 5 3/4 " D Controller Weight • 6 lbs
|