System 350
Valve systems collage

Momentary closure of the cycle start switch initiates the following events: air pressure is applied to both the material reservoir and simultaneously to the elastomer tube in the valve; as the tube collapses, material is expelled from the nozzle but pressure in the reservoir prevents flow in the opposite direction; release of air pressure from both the valve and reservoir stops the dispense; material is pulled back by the returning action of the tube following pressure release. Valve 350 photoPrecise small quantities can be repeatability dispensed by controlling the two variables: air pressure to the reservoir and degree of tube collapse (time).

System Includes:
• One 350 controller
• One Model 350 valve
• One safety reservoir system consisting of:
• 6 oz. safety retainer
• 3-6 oz. polyethylene cartridges and pistons (other size reservoir systems are available)
• One stand and clamps
• One package containing 15, 18, 20, 21, 22, 23 and 25 gauge needles
• One external filter/regulator
• C/P tips and adapter Specifications:

Power Required: 110 VAC, 50/60 Hz., 1/10 amp (220 VAC available)
Air Required: 70 psi
Controller Dimensions: 9 3/4" W x 3 3/4" H x 5 3/4" D
Weight: 12 lbs

[SoluCare Home] [Solutions] [Partners] [Contact Us]

© Drawbridge Leaders, Inc. 2006-9